Control Characteristics
Carrier Frequency 1 - 12 KHz
Frequency Control Range 0.1 - 400 Hz
Frequency Accuracy Digital: 0.01%
Analog: 0.4%
Frequency Resolution 0.01 HZ with computer of PLC control, 0.1 Hz with keypad control with frequency above 100 Hz
Frequency Setting Signal 0 - 5, 0 - 10V, 4 - 20mA, 10K Potentiometer
Optional card: Bi-polar ± 5 or ±10 Vdc command available. (Specify bi-polar command signal range)
Stall Prevention Programmable between 30% - 200%
ACCEL/DECEL Time 2 separate programmable ACCEL/DECEL times
0.1 - 3600 SEC with 2 S-curves
Programmable DECEL or free run to stop
Starting Torque 150% for up to 1 minute
Braking Torque 200V & 400V
Class
Standard braking torque = 20%
100% braking torque available with addition of optional resistors (plus braking transistors on units rated 15HP and above)
600V Class Standard braking torque = 20%
100% braking torque available with addition of optional resistors and transistors
V/f Pattern 18 patterns, one curve programmable
Output Power Circuit IGBT transistors in a sine-coded PWM (Pulse Width Modulated) firing scheme
Protection Functions
Instantaneous Overcurrent Approximately 200% of unit rated current
Overload Capacity of Drive 150% for 1 minute
Motor Overload Protection Programmable electronic thermal overload relay
Overvoltage 200V Class: DC bus exceeds 427V
400V Class: DC bus exceeds 854V
600V Class: DC bus exceeds 1050V
Undervoltage 200V Class: DC bus voltage drop < 200V
400V Class: DC bus voltage drop < 400V
600V Class: DC bus voltage drop < 500V
Momentary Power Loss Programmable 0~2 seconds: unit can be restarted via speed search
DC Bus Protection Motor coast to stop at blown fuse
Heat Sink Fin Overheat Protected by thermister/thermostat
Power Charge Indication Via charge LED
Ground Fault
Protection
Start -up Standard on all units
Running Standard on all 240V & 480V and 600V units rated above 15 amps
(Optional on all units rated 15 amps and below)
Operation Conditions
Input
Signal
Operation Signal
Forward/Reverse operation; individual command
Multifunction
Input Selection
Standard: 3 dry contact inputs only
Optional: 120 Vac interface card
Output
Signal
Multifunction
Output
1 output 35Vdc, 50mA maximum
Fault Output 250 Vac 1A, 30 Vdc 1A maximum
Built-in Functions Frequency reference bias/gain, upper lower limit, auto/manual torque boos, frequency meter gain calibration, auto reset attempt, skip frequency, S-curve: ACCEL/DECEL, current limit, carrier frequency adjust (1 - 12 KHz), communication link function, energy saver, vibration control, 7 process timers
Digital Operator Monitor Frequency command, output frequency, output current, output voltage, P-N bus voltage, rotation direction, engineering units
Analog Output Monitor Analog output (0-10V), possible to select output frequency, setting frequency, output voltage and P-N bus voltage
Environmental
Conditions
Enclosure NEMA 1 (IP20) standard, NEMA 12 (IP52), NEMA 4 (IP56) and NEMA 4X also available
Location and Altitude Indoor (protected from gas and dust) 3,300 feet (without derating). Use in an enclosure with filtered forced ventilation, or if standalone, in a clean pollution-free environment
Ambient Temperature Enclosed: -10º C to 40º C (14º F to 104º F)
Chassis: -10º C to 50º C (14º F to 122º F)
Storage Temperature -10º C to 50º C (14º F to 122º F)
Humidity 0 - 95% non-condensing
Vibration 0.5G
EMC EMC 89/336/EEC
Approvals
UL listed and Canadian UL (cUL) listed, CE Approved
(Up to 30HP, 200 & 400V Class only)