Applications
- To provide 5 VDC complementary signals for safer
data transmission over long distances between a Push-Pull, NPN, or PNP transmitter
and receiver.
- To enable devices with different output/input circuits to be connected
Installation
- Remove 4 cover screws and cover to gain access for wiring.
- Pass cables through glands and make connections according to instructions.
| Specifications |
|
|
| Supply Source |
|
8-24 VDC |
| Current Consumption |
|
60 mA @8 VDC (plus encoder requirements)
75 mA @12 VDC (plus encoder requirements)
100 mA @24 VDC (plus encoder requirements) |
| Maximum Frequency |
|
Up to 1 MHz |
| Enclosure |
|
IP54 (dust proof) |
| Earth Circuit |
|
Grounded to case |
Wiring

Dimensions (Dimensions in [ ]'s are in inches with a tolerance
of ±0.005" or ±0.01)

|